Water Treatment Plant
Prominent & Leading Manufacturer from Kolkata, we offer sewage treatment plant, reverse osmosis plant, fluoride removal plant and anti scaling compound.
Approx. Price: Rs 3,00,000 / PlantGet Latest Price Product Details:
| Feed Flow Rate (cubic-meter/day) | 100 m3/day |
| Automation Grade | Automatic |
| Impurities to be removed | Dissolved Minerals, TDS, Oil and Grease |
| Industry | Slaughter House, Sugar Industry, Pharmaceutical Industry, Chemical/Petroleum Industry |
| Voltage | 220 - 480 V |
| Water source | Industrial Effluent |
| Capacity (m3/day) | 100 m3/day, 500 m3/day |
| Power Source | Electric |
| Usage | Industry |
| Frequency | 50 - 60 Hz |
| Phase | Single, Three |
Sewage treatment, or domestic waste water treatment, is the process of removing contaminants from waste water, both runoff (effluents) and domestic. It includes physical, chemical and biological processes to remove physical, chemical and biological contaminants. Its objective is to produce a waste stream (or treated effluent) and a solid waste or sludge suitable for discharge or reuse back into the environment. This material is often inadvertently contaminated with many toxic organic and inorganic compounds. Typically, sewage treatment involves three stages, called primary, secondary and tertiary treatment. First, the solids are separated from the waste water stream. Then dissolved biological matter is progressively converted into a solid mass by using indigenous, water-borne microorganisms. Finally, the biological solids are neutralised then disposed of or re-used, and the treated water may be disinfected chemically or physically (for example by lagoons and micro-filtration). The final effluent can be discharged into a stream, river, bay, lagoon or wetland, or it can be used for the different non-critical purposes.
Advantages of our STP:-- Tailor-made design to suite customers need
- Package STP offered for housing Colonies
- Reduce Space Requirement
- Reduce Operation Cost
- Odour Removal
Typical Criteria for designing of STP’s:-- Flow in cum/day
- Inlet BOD in mg/l
- Inlet TSS in mg/l
- Outlet BOD required in mg/l
Approx. Price: Rs 2,50,000 / PieceGet Latest Price Product Details:
| Plant Application | Domestic RO Plant, Institutional RO Plant, Industrial RO Plant |
| Operation Mode | Automatic |
| RO Capacity (Liter/hour) | 0-200 (Liter/hour), 1000-2000 (Liter/hour) |
| Capacity (litres per hour) | 1000-2000, 0-200 |
| Chiller Cooling Capacity (Tons) | 1 ton, 0.5 ton |
| Number of Membranes in RO | 2 |
| Material of Construction | FRP, Stainless Steel |
| Max Water Recovery Rate | >75 % |
| Application | Industry |
| Power Source | Electric |
| Frequency | 50 - 60 Hz |
| Voltage | 220 - 380 V |
| Phase | Single, Three |
The
Reverse Osmosis Systems are engineered to economically produce high purity water by removal of dissolved minerals, bacteria, particles, and organic impurities. Each SDMRO machine is constructed using the highest quality components and materials for reliable operation and exceptional performance.
- System Features: All membrane systems are manufactured in a skid / frame design providing for ease of installation with minimum floorspace requirement. Constructed of welded structural carbon steel tubing, finished with corrosion resistant epoxy paint coating. Stainless steel fastener hardware is standard for corrosion resistance.
- Cartridge Pre-Filtration Vessel: Pre-filtration of the membrane feed is standard on all systems. Filter housing is constructed of 304 stainless steel or per client specifications. Filter cartridges are pure polypropylene with a 5.0-micron nominal rating. System Pressure Pump Standard pressure pumps are constructed 316 stainless steel housing with a glass filled noryl and lexan impeller Pumps are equipped with TEFC motors wired for 230 / 460 VAC voltage and rated for full load, continuous duty.
- Membrane Pressure Vessels: All systems feature membrane pressure vessels constructed of fiberglass reinforced polyester (FRP) with 316 stainless steel side-entry feed / concentrate ports. Standard vessels have a white polyurethane finish. ASME code stamping is available on all pressure vessels.
- Membrane Elements: Standard reverse osmosis (RO) membrane elements are high rejection, thin-film composite (TFC) type in a spiral-wound configuration. Membrane elements are tested at 99.5% average salt rejection. All membrane elements carry a three-year warranty against defects in quality and workmanship.
- Instrumentation: All systems feature a complete instrumentation package for optimal performance monitoring. Each of the following instruments are completely panel-mounted and pre-wired Pre/Post cartridge filter pressure gauges RO feed/interbank pressure gauges Product/reject pressure gauges RO inlet/pump discharge pressure switches Product/reject electronic flow meters Product conductivity monitor System temperature indicator Pump run hour meter
- System Control: Operations of the system are automatically controlled through a comprehensive programmable logic controller (PLC) package housed in a NEMA-4 industrial electrical enclosure. The control system also includes a pre-wired motor starter, operator switches / pushbuttons, and status / alarm indicator lights. Standard systems include the following isolated alarm conditions:– Low inlet pressure– High pump discharge pressure– High RO product conductivity
- System Piping & Valves: All membrane systems are completely pre-piped to the fullest extent and are installation ready. The following valves are provided as standard for accurate flow/pressure control and convenient operation:– Automatic inlet valve to prevent water flow through machine during shutdown– Pressure pump discharge throttle valve– RO reject/recirculation flow control valves– Automatic system flush valve for prevention of membrane fouling and scale formation– Pre/Post cartridge filter housing isolation valves– Inlet, product, and reject sampling valves– Isolation valves and blind ports for use with membrane cleaning systems
Approx. Price: Rs 7,00,000 / PieceGet Latest Price Product Details:
| Automatic Grade | Automatic |
| Capacity | 100 m3/Day |
| Usage | Industry |
| Application | Sugar Industry, Dairy Industry, Pharmaceutical Industry, Hotels & Resorts |
| Material | Stainless Steel |
| Voltage | 220 - 480 V |
| Frequency | 50 - 60 Hz |
| Phase | Single, Three |
| Water Source | Industrial Effluent |
| Power | 350 W |
These filters are designed for removal of fluoride for drinking water. As we know that fluoride makes incurable bone related diseases . The design of filter depend upon the concentration of fluoride in raw water. Vessels are made of HDPE/FRP/MS quality materials. Filter beds are made of High grade Activated Alumina or granular ferric hydroxide. The use of those filters are in rural drinking water solution.
Activated alumina and reverse osmosis are the only two methods for removing fluoride. Some companies claim that carbon filters will remove fluoride, but this is not correct. Also, all our Fluoride Systems use dual stage filters with activated alumina in the first stage and KDF/GAC in the second. We use the KDF/GAC cartridge to remove any activated alumina that may get into your water. Beware of companies selling a single stage filter with just activated alumina. This setup doesn't protect against activated alumina in your Treated water.
Product Price :Get Latest Price An
anti-scaling compound is a chemical formulation designed to prevent or reduce the formation of
scale deposits on metal surfaces exposed to high temperatures or water-based processes. These deposits, primarily composed of
calcium, magnesium, and silica, can decrease efficiency and damage industrial equipment.